R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319
25/46
R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.
M2 Monitoring
Code Name Min Max Unit Description
V2.1 K7 0 1 State of relay output ROD1, which controls brake contactor
V2.2 ROA1 0 1 State of relay output ROA1
V2.3 DID states .00000 .11111 State of digital input DID1-DID5, see note
V2.4 Ain1 Input 0.00 10.00 V Value of analog input Ain1
V2.5 Motor Current A Measured motor current
V2.6 Motor Voltage V Calculated motor voltage
V2.7 Heat Sink
Temperature
°C Temperature of heat sink.
V2.8 DC-link Voltage V Actual value of measured DC-link voltage.
V2.9 Frequency Reference Hz
V2.10 Output Frequency Hz Output frequency to the motor
M3 System Menu
Code Name Min Max Unit Description
S3.3 Copy parameters
P3.3.1 Parameter sets 0 = Select
1 = Store user parameters
2 = Load user parameters
3 = Store factory parameters
4 = Load factory parameters
5 = Reset parameters
6 = Fault
7 = Wait
8 = OK
S3.5 Security (not used)
P3.5.2 Parameter lock 0 = Change Enabled
1 = Change Disabled
S3.6 Keypad settings
P3.6.1 Default page Display goes to Default page after Timeout time. If value 0 is selected, this feature is not
active. Default value 2.10 “Output Frequency”
P3.6.3 Timeout time 0 65535 s Display goes to Default page after Timeout time.
S3.7 Hardware settings
P3.7.2 Fan control 0 = Continuous, default
1 = Temperature
P3.7.3 Not used
P3.7.4 Not used
S3.8 System info
S3.8.1 Counters menu
C3.8.1.1 MWh counter KWh
C3.8.1.2 Operating days
Counter
hh:mm:ss
C3.8.1.3 Operating hours
Counter
hh:mm:ss
S3.8.2 Trip counters
T3.8.2.1 MWh trip counter KWh
P3.8.2.2 Clear MWh trip
counter
T3.8.2. 3 Operating days trip
counter
T3.8.2.4 Operating hours trip
Counter
hh:mm:ss
P3.8.2.5 Clear operating time
Counter